Navegação

--------------------------------------

Ignitores DURAG

Transformadores
de Ignição HEGWEIN

Ignitores Smistvonk

Ignitores a Gás Hegwein

Ignitores a óleo Hegwein

Ignitores Bi Combustível

Ignitores / piloto Smitsvonk a Gás

--------------------------------------

Spark transformers AF...


High tension spark transformer according to DIN EN 61558-2-3:2011 for ignition of burners and igniters, designed with separate winding and PE-terminal.


AF 800 T 10
  • Applications
  • Certification
  • Technical Data
  • Downloads
  • Chemical industry
  • Refineries
  • Cement plants
  • Waste incinerators
  • Steam generators
  • Heating plants
Type AF 700 T 20 AF 800 T 10 AF 900 T 10 AF 800 T 51
Ignition electrode against earth electrode against earth electrode against earth electrode against earth
Supply voltage Standard version AF... 220-230 V AC, 50/60 Hz 220-230 V AC, 50/60 Hz 220-230 V AC, 50/60 Hz 220-230 V AC, 50/60 Hz
Supply voltage Special version AF.../00F 110-125 V AC, 50/60 Hz 110-125 V AC, 50/60 Hz 110-125 V AC, 50/60 Hz 110-125 V AC, 50/60 Hz
Supply voltage Special version AF.../00B 240-250 V AC 50/60 Hz 240-250 V AC 50/60 Hz 240-250 V AC 50/60 Hz 240-250 V AC 50/60 Hz
Power rating 2 x 100 VA 100 VA 100 VA 100 VA
Ignition voltage 2 x 5 kV 5 kV 5 kV 5 kV
Duty cycle 15% 15% 100% 15%
Protection rating IP 65 IP 65 IP 65 IP 65
Dimensions W x H x D 160 x 160 x 90 mm 122 x 120 x 81 mm 160 x 160 x 90 mm 122 x 120 x 81 mm
Weight 4 kg 1.9 kg 3.5 kg 1.9 kg
Ambient temperature - 20 °C to + 60 °C - 20 °C to + 60 °C - 20 °C to + 60 °C - 20 °C to + 60 °C
Enclosure material aluminium die casting aluminium die casting aluminium die casting aluminium die casting
Mounting position any any any any
Notes Ignition: electrode against electrode possible For igniters with combined spark/ flame rod